Rev. B, 4/13 MPX Series Magnetostrictive Level Sensors
27
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Applicaon Type 11: Curve Fit
Allows the sensor to mimic a tank strapping chart by using a 3rd degree polyno-
mial equaon to produce a “curve t” approximaon.
Register Funcon Value Range
40401 Units 1 to 3
40402 Applicaon Type 11
40404 Decimal Place 0 to 3
40406 Full Distance Typically = Blanking
40407 Empty Distance 0 to 10364 mm
40436-40437 Parameter 1 0 to 100,000 mm
40438-40439 Parameter 2 0 to 100,000 mm
40440-40441 Parameter 3 0 to 100,000 mm
40442-40443 Parameter 4 0 to 100,000 mm
Open the APG Modbus soware and select “Strapping Chart” from the “Tools”
menu.
Enter the desired data points
into the table.
Use the “Load” buon to re-
call a previously saved table.
Import data from an electronic
document by copying the data
and then using the “Paste”
buon to populate the table.